Service & parts
Spare parts, repair kits and parts lists for every YTS pump.
Order spare parts in three steps
Note the model code (for example D400GCJ) and the serial number.
Parts lists are split by serial number: up to J799999, and J800000 and above.
Request a quote and list the part numbers in the message. We will confirm the kit or individual parts and send you a quotation.
Troubleshooting chapter by pump type
- Type 031 / 030 Manual D031, 051, page 18 · Manual D030, 050, page 18
- Type 051 / 050 Manual D031, 051, page 18 · Manual D030, 050, page 18
- Type 101 Manual D101, page 18
- Type 152 Manual D152, page 18
- Type 200 Manual D200, page 22
- Type 250 Manual D250, page 22
- Type 400 Manual D400, 500, 800, page 27 · Manual D400, 500, 800-M, page 25
- Type 500 Manual D400, 500, 800, page 27 · Manual D400, 500, 800-M, page 25
- Type 800 Manual D400, 500, 800, page 27 · Manual D400, 500, 800-M, page 25
- Flap valve solids pump Manual D500AxxW, page 18
- PTFE pumps (TT) Manual D031, 051, 152, 250TT, page 22
- High-purity PTFE pumps (HT) Manual D030-400HT, page 25
- Sanitary pumps (clamped) Manual D250SWFR-A, page 18 · Manual D500SWFR, page 20
5‑year limited factory warranty
YTS diaphragm pumps are warranted to the original purchaser against defects in material and workmanship for five years from the date of shipment. YTS repairs, replaces or substitutes the defective pump or part, as determined by YTS inspection.
- Conditions: the pump is stored, installed, operated and maintained according to the YTS instructions, serviced during the warranty period by YTS or an authorised distributor, and its serial number and type plate are intact.
- Not covered: normal wear and tear, misapplication or misuse, chemical attack, corrosion, abrasion, operation beyond the specified limits, compressed air with impurities or excessive moisture, non-YTS parts, modifications, damage in transit or storage, and force majeure.
- Costs: transport to and from YTS or the designated service location, removal, reinstallation and field labour are paid by the purchaser.
- Reporting: check the goods on receipt. Report visible defects in writing within two weeks of receipt, and hidden defects within two weeks of finding them.
This is a summary. The full YTS Limited Factory Warranty applies; ask us for the complete terms.

Service without removing the pump
- The air valve on every YTS pump can be reached and replaced with the pump installed.
- Parts are sold as kits or individually.
- Service books for each type show disassembly and assembly.

FAQ
Can an AODD pump run dry?
Yes. An AODD pump can run dry for short periods without damage, but we do not recommend long dry running at high air pressure.
Can I close the discharge valve while it runs?
Yes. The pump stops when the discharge is closed and restarts when it opens; no relief valve is needed.
Is it suitable for explosive atmospheres?
AODD pumps have no electrical connection. For ATEX zones, use an ATEX version. Whether a pump is an ATEX version depends on its full model code; the ATEX table lists the ATEX versions of each type. PTFE pumps (TT) and high purity PTFE pumps (HT) have no ATEX version. Earth the pump and piping.
Does it need priming water?
No. It builds enough vacuum to self-prime.
Can it run submerged?
Yes, if the air exhaust stays above the liquid level and the materials suit the liquid.
Will it fit where my old pump was?
1" metallic pumps have a fully adjustable footprint and 1" plastic pumps have multi-footprint legs. Send us the mounting dimensions of your old pump and we will check the fit.
Need spare parts or service?
Request a quote and list the part numbers in the message, or send a service request, with the model code and serial number from the nameplate.